Understanding C by learning assembly
Last time, Alan showed how to use GDB as a tool to learn C. Today I want to go one step further and use GDB to help us understand assembly as well.
Abstraction layers are great tools for building things, but they can sometimes get in the way of learning. My goal in this post is to convince you that in order to rigorously understand C, we must also understand the assembly that our C compiler generates. I’ll do this by showing you how to disassemble and read a simple program with GDB, and then we’ll use GDB and our knowledge of assembly to understand how static local variables work in C.
Note: All the code in this post was compiled on an x86_64 CPU running Mac OS X 10.8.1 using Clang 4.0 with optimizations disabled (-O0
).
Learning assembly with GDB
Let’s start by disassembling a program with GDB and learning how to read the output. Type the following program into a text file and save it as simple.c
:
int main()
{
int a = 5;
int b = a + 6;
return 0;
}
Now compile it with debugging symbols and no optimizations and then run GDB:1
$ CFLAGS="-g -O0" make simple
cc -g -O0 simple.c -o simple
$ gdb simple
Inside GDB, we’ll break on main
and run until we get to the return statement. We put the number 2 after next
to specify that we want to run next
twice:
(gdb) break main
(gdb) run
(gdb) next 2
Now let’s use the disassemble
command to show the assembly instructions for the current function. You can also pass a function name to disassemble
to specify a different function to examine.
(gdb) disassemble
Dump of assembler code for function main:
0x0000000100000f50 <main+0>: push %rbp
0x0000000100000f51 <main+1>: mov %rsp,%rbp
0x0000000100000f54 <main+4>: mov $0x0,%eax
0x0000000100000f59 <main+9>: movl $0x0,-0x4(%rbp)
0x0000000100000f60 <main+16>: movl $0x5,-0x8(%rbp)
0x0000000100000f67 <main+23>: mov -0x8(%rbp),%ecx
0x0000000100000f6a <main+26>: add $0x6,%ecx
0x0000000100000f70 <main+32>: mov %ecx,-0xc(%rbp)
0x0000000100000f73 <main+35>: pop %rbp
0x0000000100000f74 <main+36>: retq
End of assembler dump.
The disassemble
command defaults to outputting instructions in AT&T syntax, which is the same syntax used by the GNU assembler.2 Instructions in AT&T syntax are of the format mnemonic source, destination
. The mnemonic is a human readable name for the instruction. Source and destination are operands and can be immediate values, registers, memory addresses, or labels. Immediate values are constants, and are prefixed by a $
. For instance, $0x5
represents the number 5 in hexadecimal. Register names are prefixed by a %
.
Registers
It’s worth taking a quick detour to understand registers. Registers are data storage locations directly on the CPU. With some exceptions, the size, or width, of a CPU’s registers define its architecture. So if you have a 64-bit CPU, your registers will be 64 bits wide. The same is true of 32-bit CPUs (32-bit registers), 16-bit CPUs, and so on.3 Registers are very fast to access and are often the operands for arithmetic and logic operations.
The x86 family has a number of general and special purpose registers. General purpose registers can be used for any operation and their value has no particular meaning to the CPU. On the other hand, the CPU relies on special purpose registers for its own operation and the values stored in them have a specific meaning depending on the register. In our example above, %eax
and %ecx
are general purpose registers, while %rbp
and %rsp
are special purpose registers. %rbp
is the base pointer, which points to the base of the current stack frame, and %rsp
is the stack pointer, which points to the top of the current stack frame. %rbp
always has a higher value than %rsp
because the stack starts at a high memory address and grows downwards. If you are unfamiliar with the call stack, you can find a good introduction on Wikipedia.
One quirk of the x86 family is that it has maintained backwards compatibility all the way back to the 16-bit 8086 processor. As x86 moved from 16-bit to 32-bit to 64-bit, the registers were expanded and given new names so as to not break backwards compatibility with code that was written for older, narrower CPUs.
Take the general purpose register AX, which is 16 bits wide. The high byte can be accessed with the name AH, and the low byte with the name AL. When the 32-bit 80386 came out, the Extended AX register, or EAX, referred to the 32-bit register, while AX continued to refer to a 16-bit register that made up the lower half of EAX. Similarly, when the x86_64 architecture came out, the “R” prefix was used and EAX made up the lower half of the 64-bit RAX register. I’ve included a diagram below based on a Wikipedia article to help visualize the relationships I described:
|__64__|__56__|__48__|__40__|__32__|__24__|__16__|__8___|
|__________________________RAX__________________________|
|xxxxxxxxxxxxxxxxxxxxxxxxxxx|____________EAX____________|
|xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx|_____AX______|
|xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx|__AH__|__AL__|
Back to the code
This should be enough information to start reading our disassembled program.
0x0000000100000f50 <main+0>: push %rbp
0x0000000100000f51 <main+1>: mov %rsp,%rbp
The first two instructions are called the function prologue or preamble. First we push the old base pointer onto the stack to save it for later. Then we copy the value of the stack pointer to the base pointer. After this, %rbp
points to the base of main
’s stack frame.
0x0000000100000f54 <main+4>: mov $0x0,%eax
This instruction copies 0 into %eax
. The x86 calling convention dictates that a function’s return value is stored in %eax
, so the above instruction sets us up to return 0 at the end of our function.
0x0000000100000f59 <main+9>: movl $0x0,-0x4(%rbp)
Here we have something we haven’t encountered before: -0x4(%rbp)
. The parentheses let us know that this is a memory address. Here, %rbp
is called the base register, and -0x4
is the displacement. This is equivalent to %rbp + -0x4
. Because the stack grows downwards, subtracting 4 from the base of the current stack frame moves us into the current frame itself, where local variables are stored. This means that this instruction stores 0 at %rbp - 4
. It took me a while to figure out what this line was for, but it seems that clang allocates a hidden local variable for an implicit return value from main
.
You’ll also notice that the mnemonic has the suffix l
. This signifies that the operands will be l
ong (32 bits for integers). Other valid suffixes are b
yte, s
hort, w
ord, q
uad, and t
en. If you see an instruction that does not have a suffix, the size of the operands are inferred from the size of the source or destination register. For instance, in the previous line, %eax
is 32 bits wide, so the mov
instruction is inferred to be movl
.
0x0000000100000f60 <main+16>: movl $0x5,-0x8(%rbp)
Now we’re getting into the meat of our sample program! The first line of assembly is the first line of C in main
and stores the number 5 in the next available local variable slot (%rbp - 0x8
), 4 bytes down from our last local variable. That’s the location of a
. We can use GDB to verify this:
(gdb) x &a
0x7fff5fbff768: 0x00000005
(gdb) x $rbp - 8
0x7fff5fbff768: 0x00000005
Note that the memory addresses are the same. You’ll notice that GDB sets up variables for our registers, but like all variables in GDB, we prefix it with a $
rather than the %
used in AT&T assembly.
0x0000000100000f67 <main+23>: mov -0x8(%rbp),%ecx
0x0000000100000f6a <main+26>: add $0x6,%ecx
0x0000000100000f70 <main+32>: mov %ecx,-0xc(%rbp)
We then move a
into %ecx
, one of our general purpose registers, add 6 to it and store the result in %rbp - 0xc
. This is the second line of C in main
. You’ve maybe figured out that %rbp - 0xc
is b
, which we can verify in GDB:
(gdb) x &b
0x7fff5fbff764: 0x0000000b
(gdb) x $rbp - 0xc
0x7fff5fbff764: 0x0000000b
The rest of main
is just cleanup, called the function epilogue:
0x0000000100000f73 <main+35>: pop %rbp
0x0000000100000f74 <main+36>: retq
We pop
the old base pointer off the stack and store it back in %rbp
and then retq
jumps back to our return address, which is also stored in the stack frame.
So far we’ve used GDB to disassemble a short C program, gone over how to read AT&T assembly syntax, and covered registers and memory address operands. We’ve also used GDB to verify where our local variables are stored in relation to %rbp
. Now we’re going to use our newly acquired skills to explain how static local variables work.
Understanding static local variables
Static local variables are a very cool feature of C. In a nutshell, they are local variables that only get initialized once and persist their values across multiple calls to the function where they are defined. A simple use case for static local variables is a Python-style generator. Here’s one that generates all of the natural numbers up to INT_MAX
:
/* static.c */
#include <stdio.h>
int natural_generator()
{
int a = 1;
static int b = -1;
b += 1;
return a + b;
}
int main()
{
printf("%dn", natural_generator());
printf("%dn", natural_generator());
printf("%dn", natural_generator());
return 0;
}
When compiled and run, this program prints the first three natural numbers:
$ CFLAGS="-g -O0" make static
cc -g -O0 static.c -o static
$ ./static
1
2
3
But how does this work? To understand static locals, we’re going to jump into GDB and look at the assembly. I’ve removed the address information that GDB adds to the disassembly so that everything fits on screen:
$ gdb static
(gdb) break natural_generator
(gdb) run
(gdb) disassemble
Dump of assembler code for function natural_generator:
push %rbp
mov %rsp,%rbp
movl $0x1,-0x4(%rbp)
mov 0x177(%rip),%eax # 0x100001018 <natural_generator.b>
add $0x1,%eax
mov %eax,0x16c(%rip) # 0x100001018 <natural_generator.b>
mov -0x4(%rbp),%eax
add 0x163(%rip),%eax # 0x100001018 <natural_generator.b>
pop %rbp
retq
End of assembler dump.
The first thing we need to do is figure out what instruction we’re on. We can do that by examining the instruction pointer or program counter. The instruction pointer is a register that stores the memory address of the next instruction. On x86_64, that register is %rip
. We can access the instruction pointer using the $rip
variable, or alternatively we can use the architecture independent $pc
:
(gdb) x/i $pc
0x100000e94 <natural_generator+4>: movl $0x1,-0x4(%rbp)
The instruction pointer always contains the address of the next instruction to be run, which means the third instruction hasn’t been run yet, but is about to be.
Because knowing the next instruction is useful, we’re going to make GDB show us the next instruction every time the program stops. In GDB 7.0 or later, you can just run set disassemble-next-line on
, which shows all the instructions that make up the next line of source, but we’re using Mac OS X, which only ships with GDB 6.3, so we’ll have to resort to the display
command. display
is like x
, except it evaluates its expression every time our program stops:
(gdb) display/i $pc
1: x/i $pc 0x100000e94 <natural_generator+4>: movl $0x1,-0x4(%rbp)
Now GDB is set up to always show us the next instruction before showing its prompt.
We’re already past the function prologue, which we covered earlier, so we’ll start right at the third instruction. This corresponds to the first source line that assigns 1 to a
. Instead of next
, which moves to the next source line, we’ll use nexti
, which moves to the next assembly instruction. Afterwards we’ll examine %rbp - 0x4
to verify our hypothesis that a
is stored at %rbp - 0x4
.
(gdb) nexti
7 b += 1;
1: x/i $pc mov 0x177(%rip),%eax # 0x100001018 <natural_generator.b>
(gdb) x $rbp - 0x4
0x7fff5fbff78c: 0x00000001
(gdb) x &a
0x7fff5fbff78c: 0x00000001
They are the same, just as we expected. The next instruction is more interesting:
mov 0x177(%rip),%eax # 0x100001018 <natural_generator.b>
This is where we’d expect to find the line static int b = -1;
, but it looks substantially different than anything we’ve seen before. For one thing, there’s no reference to the stack frame where we’d normally expect to find local variables. There’s not even a -0x1
! Instead, we have an instruction that loads 0x100001018
, located somewhere after the instruction pointer, into %eax
. GDB gives us a helpful comment with the result of the memory operand calculation and a hint telling us that natural_generator.b
is stored at this address. Let’s run this instruction and figure out what’s going on:
(gdb) nexti
(gdb) p $rax
$3 = 4294967295
(gdb) p/x $rax
$5 = 0xffffffff
Even though the disassembly shows %eax
as the destination, we print $rax
, because GDB only sets up variables for full width registers.
In this situation, we need to remember that while variables have types that specify if they are signed or unsigned, registers don’t, so GDB is printing the value of %rax
unsigned. Let’s try again, by casting %rax
to a signed int
:
(gdb) p (int)$rax
$11 = -1
It looks like we’ve found b
. We can double check this by using the x
command:
(gdb) x/d 0x100001018
0x100001018 <natural_generator.b>: -1
(gdb) x/d &b
0x100001018 <natural_generator.b>: -1
So not only is b
stored at a low memory address outside of the stack, it’s also initialized to -1 before natural_generator
is even called. In fact, even if you disassembled the entire program, you wouldn’t find any code that sets b
to -1. This is because the value for b
is hardcoded in a different section of the sample
executable, and it’s loaded into memory along with all the machine code by the operating system’s loader when the process is launched.4
With this out of the way, things start to make more sense. After storing b
in %eax
, we move to the next line of source where we increment b
. This corresponds to the next two instructions:
add $0x1,%eax
mov %eax,0x16c(%rip) # 0x100001018 <natural_generator.b>
Here we add 1 to %eax
and store the result back into memory. Let’s run these instructions and verify the result:
(gdb) nexti 2
(gdb) x/d &b
0x100001018 <natural_generator.b>: 0
(gdb) p (int)$rax
$15 = 0
The next two instructions set us up to return a + b
:
mov -0x4(%rbp),%eax
add 0x163(%rip),%eax # 0x100001018 <natural_generator.b>
Here we load a
into %eax
and then add b
. At this point, we’d expect %eax
to be 1. Let’s verify:
(gdb) nexti 2
(gdb) p $rax
$16 = 1
%eax
is used to store the return value from natural_generator
, so we’re all set up for the epilogue which cleans up the stack and returns:
pop %rbp
retq
Now we understand how b
is initialized, let’s see what happens when we run natural_generator
again:
(gdb) continue
Continuing.
1
Breakpoint 1, natural_generator () at static.c:5
5 int a = 1;
1: x/i $pc 0x100000e94 <natural_generator+4>: movl $0x1,-0x4(%rbp)
(gdb) x &b
0x100001018 <natural_generator.b>: 0
Because b
is not stored on the stack with other local variables, it’s still zero when natural_generator
is called again. No matter how many times our generator is called, b
will always retain its previous value. This is because it’s stored outside the stack and initialized when the loader moves the program into memory, rather than by any of our machine code.
Conclusion
We began by going over how to read assembly and how to disassemble a program with GDB. Afterwards, we covered how static local variables work, which we could not have done without disassembling our executable.
We spent a lot of time alternating between reading the assembly instructions and verifying our hypotheses in GDB. It may seem repetitive, but there’s a very important reason for doing things this way: the best way to learn something abstract is to make it more concrete, and one of the best way to make something more concrete is to use tools that let you peel back layers of abstraction. The best way to to learn these tools is to force yourself to use them until they’re second nature.
-
You’ll notice we’re using Make to build `simple.c` without a makefile. We can do this because Make has implicit rules for building executables from C files. You can find more information about these rules in the [Make manual](http://www.gnu.org/software/make/manual/make.html#Implicit-Rules). ↩
-
You can also have GDB output Intel syntax, which is used by NASM, MASM, and other assemblers, but that’s outside the scope of this post. ↩
-
Processors with SIMD instruction sets like MMX and SSE for x86 and AltiVec for PowerPC will often contain some registers that are wider than the CPU architecture.↩
-
A discussion of object formats, loaders, and linkers is best saved for a future blog post.↩